These inverters with purified inverter mode output sine AC voltage are also equipped with
in-built 3-stage battery charging system. The input AC voltage which passes to the load
during the charging mode are filtered and regulated. The transfer time for inverter to mains
operation remains at 0 sec., where mains transfer to inverter is between 2 to 4 ms. The design
concept of the inverter series made them most acceptable in the banking and telecommunication
industry. Currently the inverter can be designed from 500VA to 5KVA. The extreme hi-tech design
has really given an equipment with high power but light weight. The in-built charger capacity
can be built so suit specific need, where input voltage is also wide depending on requirements.
Other areas of use include light, computer, hair dressing, tv, music, refrigerator.
0.5K ~ 1K 2K ~ 5K

SPECIFICATION
|
PRNZ-500 |
PRNZ-1000 |
PRNZ-2000 |
PRNZ-3000 |
PRNZ-4000 |
PRNZ-5000 |
DC Input |
Input Voltage(Vdc) |
12V |
12V/24V |
24V/36V |
36V/48V |
36V/48V |
48V |
Input Current(A) |
50A |
50A |
50A |
75A |
100A |
125A |
Input DC Range(Vdc) |
10~15A |
20~30A |
40~60A |
AC Bypass |
Input AC Range(Vac) |
160V~280V |
Input Frequency(Hz) |
43~60HZ |
Bypass Voltage(Vac) |
220V¡À10% |
Input Current(A) |
2.3A |
4.5A |
9.1A |
13.6A |
18.2A |
22.7A |
Charge Current |
3~10A |
5~15A |
Transfer Time(ms) |
<=4 ms |
Output |
Output Voltage |
220V¡À3%AC |
Output Frequency |
50HZ¡À1% |
Power Factor |
0.7 |
Capacity |
350W |
700W |
1400W |
2100W |
2800W |
3500W |
Transfer time |
<=4 ms |
Generator working |
Compatible with generator well |
Waveform |
Pure Sine Wave |
Protection |
Over Temperature |
Yes |
Over Voltage |
Switch to battery output when mains beyond standard regulation range |
Under voltage |
Over load |
Fuse current limited for both mains and battery modes |
Short circuit |
Function |
Panel |
LED Display |
Automatic charge |
When UPS is off automaict charge by mains |
Automatic recovery |
After battery off UPS automatic shutdown, within 1 hour if mains coming
then UPS can automatic recover to start.
|
Voltage |
220V/230V optional by CPU following the real power capacity |
Frequency |
50Hz/60Hz optional by CPU following the real power capacity |
Beeping |
During the battery mode, the beeping sound or slience optional |
Environmental |
Temerature |
-20oC ~ 45oC |
Humidity |
0% ~ 95% |
Noise |
¡Ü40dB (1meter) |
Physical |
Net Weight |
9.5kg |
15kg |
19.5kg |
26.5kg |
30.5kg |
36kg |
Gross Weight |
12kg |
18kg |
23kg |
30kg |
34kg |
39kg |
Dimension for Unit |
465 x 145 x 235 mm |
470 x 200 x 355 mm |
Dimension for Packing |
510 x 220 x300 mm |
575 x 310 x 455 mm |
Output socket |
2outlets |
2outlets |
3outlets |
3outlets |
3outlets |
3outlets |
| ¡¡ |
|